Process Cooling tailored to your company’s needs.

Industrial cooling and tempering solutions for injection molding, thermoforming, injection molding, extruding, blow molding, rotational molding, process collation, intrusion batches and calendering.

KOELING COMPOSITIE

Before the start of a cooling project, we are happy to evaluate the specifications and elaboration options together with you.

We always design the optimal cooling arrangement adapted to your needs:

  • We look at how we can best use the specified location.
  • Which type of cooling system best fits your specific project
  • Which peripheral equipment can possibly be used to save energy and to use freecooling.

Elements of a cooling installation

Below we briefly explain the various elements and possibilities of both central and decentralized cooling principles.

Central cooling

With central cooling, 1 chiller sends cooling to multiple users throughout production.

centrale koeling pme tekening

Benefits

  • Higher efficiency when a similar temperature is required throughout production.
  • Contains high-quality screw compensators that last longer.

Decentralized Cooling

Decentralized cooling has several chillers that cool separate consumers separately.

Benefits

  • Multiple temperature set points possible
  • Less frequent maintenance required compared to central cooling
  • The control and controls can be simplified.
  • Cooling is tailored to each specific part of the production

The system can still be moved afterwards and used for other cooling purposes

Used coolers and peripherals

Chiller

Industrial Chiller Medium Heavy Duty Frigel 3HM_MRM

A chiller is a forced cooling by means of a compressor.
Set point between 5 ° C and 20 ° C regardless of the ambient temperature

Specifications

  • Screw compressors
  • Multiscrol compressors
  • Water cooled
  • Air cooled
  • Cooling capacity: 50 kW – 1000 kW

Free cooling*

A free cooler takes in ambient air and, together with built-in fans, ensures a high cooling capacity.

Depending on the needs of the customer, the installation of a free cooler can provide a significant return *.

* The potential return mainly depends on the desired set temperature compared to the average outside temperatures throughout the year.

3DK-10-Fans-Selfdraining_Frigel_vrijkoelers_koelingsinstallatie

Standard

  • Frequency regulated regulators
  • Cooling capacity: 50 kW – 1000 kW
  • Stainless version (Inox)

Adiabatic

  • Frequency regulated regulators
  • Cooling capacity: 50 kW – 1000 kW
  • Stainless version (Inox)
  • Cooling to ambient temperature
  • Adiabatic chamber is also a pollen filter

Microgel

  • Compact water-cooled chiller with flexible set point per consumer.
  • Fits perfectly in a decentralized cooling installation.

Characteristics:

  • Water cooled chiller
  • Local cooling on the machine
  • temperature set point: between 5 ° C and 90 ° C
  • Cooling capacity: 50 kW – 180 kW
  • 2-set temperatures possible on one unit
Industrial temperature control microgel

Hydraulics

Buffer and transport of coolant.

Specifications

  • Grundfos modular pump groups
  • Frequency control
  • Isolated tanks: 1000 l / 2000 l / 3000 l
    Water or glycol as a medium
Pompgroep_frigel_koelingsysteem

Control

The control is the central interface of the entire cooling installation.

Characteristics

  • Standard control
  • PLC controlled
  • Customer specific
3PR-Cooling-sturing-console-controller